GENERAL
Non-corrosive die-cast aluminium (anticorodal)
Epoxy powder painted with orange peel effect, RAL7032
MECHANICAL
2 holes for cable glands 3/4" NPT
External dimensions:
EXHC Ø 210mmx427.5mm (8.2x16.8in)
EXHD Ø 250x573.5mm (9.8x22.6in)
Internal dimensions:
EXHC Ø 180x380mm (7x14.9in)
EXHD Ø 180x460mm (7x18.1in)
Internal usable area:
EXHC 100x100x280mm (3.9x3.9x11in)
EXHD 100x100x280mm (3.9x3.9x11in)
Glass window:
EXHC Ø 114mm (4.5in)
EXHD 70x56mm (2.7x2.2in)
Unit weight:
EXHC 15kg / 33lb
EXHD 24kg / 52.9lb
Glass protection device:
Glass protection device: Ø 250x140mm (9.8x5.5in)
Mylar film 80mm (3.1in) wide and 18m (59ft) length, 350 shifting steps, marks printed on the last 50cm (19in)
ELECTRICAL
Reinforced heater: Ton 15°C±4°C (59°F±7°F), Toff 22°C±3°C (72°F±5°F)
3 resistors in the housing, consumption 60W max
Glass protection device:
24Vac, power consumption 2W max
Devices to install inside the housing
Camera equipped with lens with max total power of 20W
Voltage max. 24Vac or 230Vac
Useful volume for camera / lens: 2800cm ³
Minimum distance between the walls of the housing and the camera/lens: 12mm
ENVIRONMENT
For installation indoors and outdoors
Operating temperature with heating: -40°C / +50°C (-40°F/+122°F)
Always refer to the temperature in the marking.
CERTIFICATIONS
ATEX (EN 60079-0: 2009, EN 60079-1: 2007, EN 60079-31: 2009):
Ex II 2G Ex d IIC T6 Gb
Ex II 2D Ex t IIIC T85 °C Db IP66
0044: notify number from competent body
IECEx (IEC 60079-0: 2007, IEC 60079-1: 2007, IEC 60079-31: 2008):
Ex d IIC T6 Gb
Ex t IIIC T85 °C Db IP66
EAC EX:
Ex II 2G Ex d IIC T6 Gb,-40°C/+50°C
EX II 2D Ex t IIIC T85°C Db -40°C/+50°C, IP66
KCs 16-KA4BO-0057 -16-KA4BO-0058
Ex d IIC T6
Ex tb IIIC T85°C
Industry : Surface II
Environment : Gas Environment : Dust
Protection type : EExd -
Gas : II C
Area : 1 2 21 22 Materials : Aluminium cast |